| PRODUCT RANGE
|
![]()
|
![]() |
NSW-193 "CALTAN" PLANT GROWTH CHAMBERS
(SMALL)
Inside made of Anodized Aluminium
outside Mild Steel with epoxy powder coating fitted with cooling,
heating and lighting arrangement.Temperature range 5°C
to 50°Cti °C Temperature can be obtained from
15°C to 50°C±1 °C
when all lights from two sides and top are 'ON', temperature is controlled
by DUAL temperature electronic Digital Temperature
Controller-cum-indicator to set two temperature for day and night. Above
Growth chamber is complete with Humidity control from 55% to 95% at cool
temperature. Light intensity can be adjusted by controller according to
requirement and humidity is controlled by humidistat which gets completed
with 0-24 hrs.Timer.
|
||||||||||||
![]() |
NSW-193 "CALTAN" PLANT GROWTH CHAMBERS
(LARGE)
A versatile controlled
Environment Chamber useful for plant growth & animal studies. This
Chamber provides the necessary light, enclosed humid atmosphere and
warmth for successful plant growth in a laboratory. Suitable for
investigation in the eftect of day light on flowering cycle, growth rate
etc. The Chamber is double walled insulated with 75mm thick super glass
wool between interior and exterior walls. Outer chamber is made of mild
steel and finished with durable epoxy powder coating paint. The inner
chamber is made of stainless steel 304 Olty. The chamber shall have full
view inner acrylic door which will allow inspection of samples without
disturbing the temperature of working chamber. The plant growth chamber
shall be mounted on casters for smooth shifting of chamber from one place
to another. The chamber shall be supplied with three number .heavy
dutystainless steel shelves. Viewing window having dimension 35cm x
35cm shall be given on the two sides with flourecent tube lights if you
want to switch off the tube light natural light may be given in the
chamber from the two sides.
PHOTOPERIODIC SYSTEM The temperature in the chamber is controlled by dual temperature micro processed based Electronic Indicator-cum-controlled to regularise the two temperatures one for day and one for night with the help of microprocessed 7 days programmable Timer. Temperature may be controlled from 15°C to50°C. In day time when the full lights are on. COOLING SYSTEM The chamber has cooling system by sealed compressor with all accessories and fan cooled condensor are fitted at the bottom exactly below the working chamber to give efficient cooled desired temperature. LIGHTING SYSTEM The chamber has provision to give light upto 50Kx (50,000 Lux) from the top of the chamber. The growth chamber has been made to control the light intensity thus it gives microclimate radiation stimulated spectrum adjustable 50 K Lux. Light intensity may given on higher side if is required. We give mixture of light by incandescent lamp, fluorescent lamps and sodium vapour lamps. HUMIDITY CONTROL SYSTEM Humidity in the chamber is controlled from 55% to 95% by Humiditistat and injection of water vapour inside chamber thus making the environment in controlled condition. To work on 220 Volt A.C.5O Cycle complete with voltage stabilizer.
|
|||||||||||||||